Napl TAC16P single-phase power controller for voltage regulation/power regulation
Napl TAC16P single-phase power controller integrating voltage regulation and power regulation
Maximum Current 1500A
■New product developed by applying high-power solid-state relay (SSR) technology
■Integration of single-phase voltage regulation and power regulation, selectable power regulation mode: cycle or duty-cycle (PWM)
■Microprocessor digitization design, phase-locked loop synchronous circuit, 3VAC low-voltage start-up, slow start-up after powerup, slow turn-off, heatsink over-temperature alarm, current limit, over-current protection, manual/automatic switching balanceless, etc.
■current capacity:30A 50A 80A 105A 150A 195A 255A 300A 600A
1000A 1500A(click on the current to see photographs)
■Control PCB voltage:220V AC/380V AC
■Applicable to resistive load and inductive load, capable of effectively controlling loads such as SiC rod, Silicon molybdenum rod,
electric heating tube, nichrome wire, transformer, etc.
I. Selection Form:
Item |
Code |
Specification |
|||||||
Series |
TAC16P |
One Phase Power Regulator |
|||||||
Control input |
4- |
4~20 mA DC, Receiving impedance: 120Ω |
|||||||
6- |
0~10 V DC, Impedance of input: 450KΩ |
||||||||
Power supply |
22- |
220V AC±10% 50HZ |
|||||||
38- |
380V AC±10% 50HZ |
||||||||
90- |
220V/380V AC±10% 50HZ/60HZ |
||||||||
Current capacity External dimension Weight |
030- |
30A AC 220 H× 94 W×140 D |
|||||||
050- |
50A AC 220 H× 94 W×140 D |
||||||||
080- |
80A AC 245 H×110 W×203 D |
||||||||
105- |
105A AC 245 H×110 W×203 D |
||||||||
150- |
150A AC 245 H×110 W×203 D |
||||||||
195- |
195A AC 376 H×132 W×265 D |
||||||||
255- |
400A AC 376 H×132 W×265 D |
||||||||
300- |
500A AC 376 H×132 W×265 D |
||||||||
Current limit & Over current alarm Option |
N |
None |
|||||||
C |
Enable |
||||||||
Zero-cross firing mode Option |
00 |
None |
|||||||
01 |
For resistance load |
||||||||
04 |
For transformer load |
||||||||
Rapid fuse |
N |
Without |
|||||||
F |
With |
II. Ordering Information:
1.Reference for selection of current capacity of power controller
- Common pure resistance load: the current capacity of the selected power controller must be greater than the maximum current of the load.
- SiC Rod Load: when the transformer is removed, SiC rod should be connected in series, so that it can withstand at least 70%~80% of the power supply voltage. As for the SiC rod, there will be a negative impedance region when the temperature ranges from 700℃ to 800℃, and the selected current capacity should be 1.3 times greater than the current of the load.
- Electric Heating Tube Load: the electric heating tube load can be easily affected with damp as well as partial short circuit, and the selected current capacity should be 1.3 times greater than the current of the load.
- Transformer Load: current limit function should be provided, and the current capacity of the selected power controller should be 1.5 times greater than the current of the load.
- Order Example:TAC16P4-22-080-N00F
Example 1:TAC16P4-22-080-N00F is defined as follows :
TAC16P single-phase power controller, 4~20mA control signal input, power suppy voltage of control PCB and load 220V, current capacity 80A, provided with quick fuse (Maximum current of pure resistance load 80A; Maximum current of SiC stick load and electric heating tube load 62A; Maximum current of transformer load 53A )
Example 2:TAC16P-90-080-I00F is defined as follows:
TAC16P single-phase power controller, 4~20mA control signal input, power supply voltage of control PCB 220VAC/380VAC, frequency 50HZ/60HZ, current capacity 80A (Maximum current of pure resistance load 80A; Maximum current of SiC stick load and electric heating tube load 62A; Maximum current of transformer load 53A ), provided with constant current control, current limit, and over-current alarm, as well as quick fuse.